Equipment tests
Is your product suitable for use in the intended electromagnetic environment?
With our testing options, you receive proof of compliance with the following standards and regulations:
- VG 95370/373
- MIL-STD 461/462
- RTCA DO-160
Our portfolio of services
Interference emission measurements
- Interference currents: 20 Hz to 400 MHz
- Interference voltages: 20 Hz to 100 MHz
- Interference fields: 0 Hz to 30 MHz (magnetic fields), 10 kHz to 18 GHz (40 GHz) (EM field)
Immunity to
- Pulse disturbances: various pulse shapes (high-energy pulses, bursts)
- Electrostatic discharges (ESD): Air/contact discharge
- Interference fields: 0 Hz to 30 MHz (magnetic fields), 10 kHz to 18 GHz (EM field)
Measuring rooms
RF anechoic chamber, large: 685 cm x 403 cm x 420 cm (W x D x H)
Door: 295 cm x 303 cm)
Installations:
- 3 x 400 V / 230 V, 50 Hz 100 A
- 3 x 115 V / 67 V, 400 Hz 50 A
- 3 x 115 V / 67 V, 60 Hz 100 A
- 3 x 440 V / 254 V, 60 Hz 32 A
- 220 VDC 100 A
RF anechoic chamber, small: 438 cm x 320 cm x 213 cm (W x D x H)
Door: 94 cm x 212 cm)
Installations:
- 3 x 400 V / 230 V, 50 Hz 32 A
- 3 x 115 V / 67 V, 400 Hz 25 A
For test infrastructure outside the anechoic chamber
- 3 x 400 V / 230 V, 50 Hz 63 A
- 3 x 115 V / 67 V, 400 Hz 32 A
- 3 x 115 V / 67 V, 60 Hz 32 A
- 220 VDC 32 A
- Various DC voltages and special voltages by arrangement
Think Differently –